DC Brake VersiBrake L (LP) Series(6-30A)
![]() |
Features:
|
Functions:
Typical Applications: |
![]() |
Models:
|
Type designation |
AC-VB 230-6L |
AC-VB 230-25L |
AC-VB 230-30L |
AC-VB 400-6L |
AC-VB 400-25L |
AC-VB 400-30L |
|
Mains voltage according to DIN EN 50160 (IEC 38) |
220/240V ± 10% 50/60Hz |
380/415V ± 10% 50/60Hz |
||||
|
Power draw of the electronics |
3VA |
|||||
|
Recommended for rated motor currents up to |
0.3 … 3A |
2 … 12.5A |
2 … 15A |
0.3 … 3A |
2 … 12.5A |
2 … 15A |
|
Rated device current |
6A |
25A |
30A |
6A |
25A |
30A |
|
max. Braking frequency at a braking time of 5s |
1/8s |
1/60s |
1/90s |
1/8s |
1/60s |
1/90s |
|
I2t-Value Power semiconductor (A2s) |
310 |
1250 |
1350 |
310 |
1250 |
1350 |
|
Braking voltage |
0 … 110VDC |
0 … 220VDC |
||||
|
max. Braking time |
12s |
|||||
|
Contact rating (control relay) |
3A/250VAC; 3A/30VDC |
|||||
|
Delay time for reduction of residual e.m.f. |
Self-optimizing in the range between 0.2 … 2s |
|||||
|
max. Cross-sectional area for connection |
2x 2.5mm2 per terminal |
|||||
|
Ambient / Storage temperature |
0ºC … 45ºC / -25ºC … 75ºC |
|||||
|
Weight / kg |
0.6 |
|||||
|
Order number case version (L) |
2B000. 23006 |
2B000. 23025 |
2B000. 23030 |
2B000. 40006 |
2B000. 40025 |
2B000. 40030 |
|
Order number printed circuit-board version (LP) |
2B100. 23006 |
2B100. 23025 |
2B100. 23030 |
2B100. 40006 |
2B100. 40025 |
2B100. 40030 |
|
Please observe supplementary sheet with dimensioning rules |
||||||
Dimensions:

Connection Diagram: